GENERATOR | ||||||
Generator Type | Rotating Field, Brushless 3-Phase Synchronous Alternator | Winding | 3-Phase, 4-Wire | |||
Rated Frequency | Hz | 50 | 60 | Power Factor | % | 80 |
Rated Output | kVA | 50 | 60 | Insulation Class | F | |
kW | 40 | 48 | Excitation | Self-Excitation (Brushless) | ||
Rated Voltage | V | 400 [200] | 440 [220] | Number of Poles | 4 |
UNIT | *Reference value | |||||
Length | mm | 2090 | Dry Weight | kg | 1180 | |
Width | mm | 880 | Installed Weight | kg | 1320 | |
Height | mm | 1240 |
Sound Level |
50Hz | 59* | |
@7m distance/No load | 60Hz | 62* |
ENGINE | *Reference value | |||||
Types | Vertical Water-Cooled 4-Cycle Diesel Engine | Fuel Consumption L/Hr | 50Hz | 8.7* | ||
Model | BB-4BG1T (ISUZU) | @3/4 load | 60Hz | 10.7* | ||
Number of Cylinders | 4、105 (bore) x 125 (stroke) mm | Fuel | Diesel Fuel | |||
Continuous Rated Output | kW | 48.3 | 57.8 | Lubricant Oil | CD Class | |
Rated Speed | min-1 | 1500 | 1800 | Fuel Tank Capacity | 125 | |
Displacement | L | 4.329 | Lubricant Volume | L | 14.3 | |
Combustion System | Direct Fuel Injection with Turbo Charger | Cooling Water Volume | L | 15.4 | ||
Cooling Method | Radiator | Battery | 95D31R | |||
Lubricating Method | Full Forced Pressure Feed Type | |||||
Starting Method | Electric Start |
Control Panel
- Hour Meter
- Pilot Lamp
- Earth Leakage Relay
- Warning Indicators
- Voltmeter
- Ammeter
- Frequency Meter
- Circuit Breaker
- Fuel Gauge
- 400/440V Output Lamp
- Over Load Precaution Lamp
- Preheat Lamp
- Water Temperature Gauge
- Voltage Regulator
- Starter Switch
- Ammeter Selector
- Throttle Lever
- Frequency Adjusting Screw
Feature
Double Fuel Filtration System
The unit has two fuel filtration; one is a fuel filter and the other is a water separator with enhanced water filtration capability. Elimination of debris such as water, sand, and dust is ensured by double fuel filtration system, and reduces maintenance frequency.
Over Load Precaution Lamp
The lamp starts to flash if the output current exceeds 80% of the rated current.
Socket for Industrial Use
Socket for industrial use (IP44) *1, widely used at job site, is equipped as standard. It is ready-to-use for
“turn-key” operation.
*1 3-Phase round 4 pins (32A) x 1
1-Phase round 3 pins (15A) x 2
Theft Protection
Every door can be locked.Simple Control Panel
As the functions are limited to the minimum necessary levels, arrangement of the control panel is simplified, thereby reducing the risk of an improper operation.
Reliable ISUZU Engine
DG60MI-400 is equipped with ISUZU BB4B1T.
As ISUZU service network covers the world, it offers extensive services, periodical inspection, and repair.